Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 162
Filtrar
1.
World J Urol ; 42(1): 240, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38630158

RESUMO

PURPOSE: To evaluate the impact of ureteroscope position within renal cavities as well as different locations of the tip of the ureteral access sheath (UAS) on fluid dynamics during retrograde intrarenal surgery (RIRS). MATERIALS AND METHODS: A prospective observational clinical study was performed. Measurements with a flexible ureteroscope placed in the upper, middle and lower calyces were obtained with the tip of the UAS placed either 2 cm below the pyelo-ureteric junction (PUJ), or at the level of the iliac crest. RESULTS: 74 patients were included. The outflow rates from the middle and upper calyxes were statistically significantly higher compared to the lower calyx, both with the UAS close to the pyelo-ureteric junction and at the iliac crest. When the UAS was withdrawn and positioned at the level of the iliac crest, a significant decrease in outflow rates from the upper (40.1 ± 4.3 ml/min vs 35.8 ± 4.1 ml/min) and middle calyces (40.6 ± 4.0 ml/min vs 36.8 ± 4.6 ml/min) and an increase in the outflow from the lower calyx (28.5 ± 3.3 ml/min vs 33.7 ± 5.7 ml/min) were noted. CONCLUSIONS: Our study showed that higher fluid outflow rates are observed from upper and middle calyces compared to lower calyx. This was true when the UAS was positioned 2 cm below the PUJ and at the iliac crest. Significant worsening of fluid dynamics from upper and middle calyces was observed when the UAS was placed distally at the level of the iliac crest. While the difference was statistically significant, the absolute change was not significant. In contrast, for lower calyces, a statistically significant improvement was documented.


Assuntos
Ureter , Ureteroscópios , Humanos , Hidrodinâmica , Rim , Endoscopia , Ureter/cirurgia
2.
World J Urol ; 42(1): 163, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38488927

RESUMO

INTRODUCTION: Due to the radiation exposure for the urology staff during endourology, our aim was to evaluate the trends of radiation protection in the operation room by endourologists from European centers and to estimate their annual radiation. METHODS: We conducted a multicenter study involving experienced endourologists from different European centers to evaluate whether the protection and threshold doses recommended by the International Commission on Radiation Protection (ICRP) were being followed. A 36-question survey was completed on the use of fluoroscopy and radiation protection. Annual prospective data from chest, extremities, and eye dosimeters were collected during a 4-year period (2017-2020). RESULTS: Ten endourologists participated. Most surgeons use lead aprons and thyroid shield (9/10 and 10/10), while leaded gloves and caps are rarely used (2/10 both). Six out of ten surgeons wear leaded glasses. There is widespread use of personal chest dosimeters under the apron (9/10), and only 5/10 use a wrist or ring dosimeter and 4 use an eye dosimeter. Two endourologists use the ALARA protocol. The use of ultrasound and fluoroscopy during PCNL puncture was reported by 8 surgeons. The mean number of PCNL and URS per year was 30.9 (SD 19.9) and 147 (SD 151.9). The mean chest radiation was 1.35 mSv per year and 0.007 mSv per procedure. Mean radiation exposure per year in the eyes and extremities was 1.63 and 11.5 mSv. CONCLUSIONS: Endourologists did not exceed the threshold doses for radiation exposure to the chest, extremities and lens. Furthermore, the ALARA protocol manages to reduce radiation exposure.


Assuntos
Exposição Ocupacional , Exposição à Radiação , Proteção Radiológica , Humanos , Estudos Prospectivos , Exposição Ocupacional/prevenção & controle , Fluoroscopia/efeitos adversos , Exposição à Radiação/prevenção & controle , Doses de Radiação
3.
World J Urol ; 42(1): 188, 2024 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-38520528

RESUMO

PURPOSE: Artifacts from poor ureteroscopes' light design with shadowing and dark areas in the field of view have been reported. The aim was to quantify effects of light obstruction in a kidney calyx model. METHODS: We evaluated a series of contemporary flexible ureteroscopes including the Storz Flex-Xc and Flex-X2s, Olympus V3 and P7, Pusen 7.5F and 9.2F, as well as OTU Wiscope using an enclosed 3D-printed pink in vitro kidney calyx model submerged in saline, where the field of light was intentionally partially obstructed alternatively at 12, 3, 6, and 9 o'clock. A color spectrometer was used for illuminance measurements at a 45° opening position in the background of the model. RESULTS: Overall and mean background illuminance for each obstructive situation were significantly different between scopes for both 50% and 100% brightness settings (ANOVA p < 0.001). At 50% brightness setting, almost all scopes had their highest and lowest background illuminance with the 6 o'clock and 3 o'clock obstructive situation, respectively. At 100% brightness setting, these became 6 o'clock and 12 o'clock obstructive situations. Considering each obstructive situation individually, the Flex-Xc was consistently the scope with highest background illuminance and the Pusen 7.5F the lowest. Background illuminance for each obstructive situation varied significantly for each scope individually, with the greatest range of variability for Pusen 7.5F and V3. CONCLUSIONS: Illuminance performance of ureteroscopes within an obstructed calyx model differ significantly for various obstructive situations. Urologists should be aware of this to help guide their choice of ureteroscope.


Assuntos
Iluminação , Ureteroscópios , Humanos , Desenho de Equipamento , Urologistas , Equipamentos Descartáveis , Ureteroscopia
4.
World J Mens Health ; 2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-38449455

RESUMO

PURPOSE: We aimed to investigate the relationship between follicle stimulating hormone (FSH) and inhibin B (InhB). MATERIALS AND METHODS: Data from 1,230 consecutive men presenting for primary couple's infertility were analyzed. Health-significant comorbidities were scored with Charlson comorbidity index. Quartiles of FSH and InhB were considered to determine threshold values. Descriptive statistics and logistic regression models tested association between FSH and InhB values. RESULTS: Overall, 1,080 (87.8%) men had concordant FSH and InhB values. Conversely, 150 patients (12.2%) had discrepancies in FSH and InhB, with 78 (6.3%) and 72 (5.9%) men reporting both low and high FSH and InhB values, respectively. Infertile men with discordant values were younger (median [interquartile range] 38.0 years [34-41 years] vs. 36.0 years [31-40 years]); had smaller testicular volume (TV) (12 mL [10-15 mL] vs. 15 mL [12-20 mL]); and, had more frequently a sperm DNA fragmentation test >30% (179 [59.1%] vs. 40 [78.4%]) than those with concordant values (all p<0.05). Moreover, a higher frequency of previous cryptorchidism (27.3% vs. 11.9%), lower sperm concentration (3.0 million/mL [0.9-11.0 million/mL] vs. 13.8 million/mL [3.1-36.0 million/mL]), lower progressive sperm motility rates (12.0% [5.0%-25.3%] vs. 20.0% [7.0%-36.0%]), and greater rates of non-obstructive azoospermia (36.4% vs. 23.9%) were found in men with discordant FSH and InhB values (all p≤0.005). At multivariable logistic regression analysis, higher body mass index (odds ratio [OR], 1.08; p=0.001), smaller TV (OR, 0.91; p<0.001), and a history of cryptorchidism (OR, 2.49; p<0.001) were associated with discordant FSH and InhB values. CONCLUSIONS: More than one out of ten infertile men had discordant FSH and InhB values in the real-life setting showing worse clinical profiles than those with concordant levels. Smaller TV and history of cryptorchidism could be used as clinical markers to better tailor the need to test InhB.

5.
World J Urol ; 42(1): 145, 2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38478094

RESUMO

INTRODUCTION AND OBJECTIVES: Medical device companies have introduced new TFL machines, including Soltive (Olympus, Japan), Fiber Dust (Quanta System, Italy), and TFLDrive (Coloplast, France). The primary objective of this study is to compare our initial clinical experiences with TFL using those devices. Through this historical comparison of Thulium Fiber Laser systems for stone lithotripsy, we aim to advance our understanding and approach toward achieving safe and effective TFL parameters. MATERIALS AND METHODS: The data for this comparative analysis were extracted from three distinct prospective series that were previously published, outlining our initial clinical experience with the Soltive (Olympus, Japan), FiberDust laser (Quanta System, Italy), and TFLDrive laser (Coloplast, France). Parameters such as stone size, stone density, laser-on time (LOT), and laser settings were meticulously recorded. Additionally, we assessed critical variables such as ablation speed (expressed in mm3/s) and Joules/mm3 for each lithotripsy procedure. RESULTS: A total of 149 patients were enrolled in this study. Among them, 120 patients were subjected to analysis concerning renal stones. Statistically significant differences were observed in the median (IQR) stone volume: 650 (127-6027) mm3 for TFLDrive, 1800 (682.8-2760) mm3 for Soltive, and 1125 (294-4000) mm3 for FiberDust (p: 0.007); while there were no differences regarding stone density among the groups. Significant variations were identified in median (IQR) pulse energy, frequency, and total power. The Soltive group exhibited lower energy levels (0.3 J vs. 0.6 J, p: 0.002) but significantly higher pulse frequency (100 Hz vs. 17.5 Hz, p: 0.003) and total power (24 W vs. 11W, p: 0.001) compared to the other groups. Laser-on time showed no substantial differences across all three groups. Additionally, a statistically significant difference was observed in median J/mm3, with the TFLDrive group using higher values (24 J/mm3, p: 0.001), while the Soltive group demonstrated a higher median ablation speed of 1.16 mm3/s (p: 0.001). The overall complication rate remained low for all groups, with comparable stone-free rates. CONCLUSION: By reducing pulsed frequency, we improved laser efficiency, but smaller volumes lead to decreased efficiency due to increased retropulsion and fragment movement. Further studies are needed to identify and establish the appropriate laser settings for this new technology.


Assuntos
Cálculos Renais , Lasers de Estado Sólido , Litotripsia a Laser , Litotripsia , Humanos , Túlio/uso terapêutico , Litotripsia a Laser/métodos , Cálculos Renais/cirurgia
8.
Cent European J Urol ; 76(3): 245-250, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38045778

RESUMO

Introduction: The area of paediatric endourology is unique and is recognised to be challenging, and it requires a certain level of focused training and expertise. Our aim was to conduct a worldwide survey in order to gain an overview regarding the current practice patterns for minimally invasive treatments of paediatric upper urinary tract stone patients. Material and methods: The survey was distributed between December 2021 and April 2022 through urology sections and societies in United Kingdom, Latin America and Asia. The survey was made up of 20 questions and it was distributed online using the free online Google Forms (TM). Results: 221 urologists answered the survey with 56 responses each from India, South America and UK and 53 responses from the rest of Europe (15 countries). In total, 163 responders (73.7%) managed paediatric stone patients in their daily practice. Of the responders, 60.2% were adult urologists and 39.8% were paediatric urologists. 12.9% adult urologists and 20.4% paediatric urologists run independent clinics while some run combined adult and paediatric clinics sometimes with the support of the nephrologists. Only 33.9% urologists offered all surgical treatments [extracorporeal shock wave lithotripsy (ESWL), percutaneous nephrolithotomy (PCNL), ureteroscopy (URS) and retrograde intrarenal surgery (RIRS)]. Conclusions: Treatment of paediatric stones can vary according to country and legislations. Based on the results of this survey, minimally invasive methods such as URS and mini PCNL seem to have become more popular. In most institutions a collaboration exists between adult and paediatric urologists, which is the key for a tailored decision making, counselling and treatment success.

9.
Eur Urol Open Sci ; 58: 82-86, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38152483

RESUMO

Background: Both clinicians and patients use social media to post about health care issues such as kidney stone disease, but their perspectives may differ. Objective: To evaluate content and themes regarding kidney stone surgery shared by patients and urologists on Instagram. Design setting and participants: A search was performed on Instagram using the term "kidney stone surgery". The first 100 posts from individuals who were clearly identified as a patient were assessed. We also assessed 100 posts from self-identified urologists. Outcome measurements and statistical analysis: A previously published system was applied as a framework for categorizing the information collected. Outcomes of interested included pain, recovery, and costs. Results and limitations: Some 71% of the patients were female and most of their posts (52%) were shared postoperatively. The most common themes covered in patient posts were the need for multiple operative sessions (45%), pain (43%), and recovery (42%). Other themes included activities of daily life (18%), return to work (11%), nervousness (16%), stent issues (31%), stent on a string (5%), diet and prevention (9%), gratitude for health care services (10%), disease recurrence (18%), and costs (10%). Some 94% of the urologists were male and their posts covered the following domains: recovery (11%), stent issues (3%), pain (1%), stent on a string (1%), gratitude for health care services (1%), and recurrence 1%. Among the posts from urologists, 79% included self-promotion and 52% covered new technology. Overall, 10% contained false information. The majority of the posts with surgical images had no clear statement regarding patient consent (97%). Conclusions: Kidney stone surgery can affect many areas of a patient's quality of life. Most of the posts shared by patients were negative. Posts shared by urologists do not reflect the same themes. Moreover, there appears to be poor adherence to European Association of Urology recommendations regarding online professional conduct. Patient summary: Many patients use social media to share their experiences of kidney stone surgery. Posts are largely related to quality-of-life issues and are mostly negative. While urologists also use social media, the content they post on professional accounts is mostly focused on new technology and career promotion.

10.
Eur Urol Focus ; 2023 Nov 06.
Artigo em Inglês | MEDLINE | ID: mdl-37940392

RESUMO

CONTEXT: Laser performance for lithotripsy is currently reported using units of measurement such as J/mm3, mm3/J, mm3/s, s/mm3, and mm3/min. However, there are no current standardized definitions or terminology for these metrics. This may lead to confusion when assessing and comparing different laser systems. OBJECTIVE: The primary objective was to summarize outcome values and corresponding terminology from studies on laser lithotripsy performance using stone volume in relation to time or energy. The secondary objective was to propose a standardized terminology for reporting laser performance metrics. EVIDENCE ACQUISITION: A systematic review of the literature was conducted using the search string ("j*/mm3" OR "mm3/j*" OR "mm3/s*" OR "s*/mm3" OR "mm3/min*" OR "min*/mm3" AND "lithotripsy") on Scopus, Web of Science, Embase, and PubMed databases. Study selection, data extraction, and quality assessment were performed independently by two authors. EVIDENCE SYNTHESIS: A total of 28 studies were included, covering holmium:yttrium-aluminum-garnet (Ho:YAG), MOSES, and thulium fiber laser (TFL) technologies. Laser energy consumption values reported for the studies ranged from 2.0 - 43.5 J/mm3in vitro and from 2.7 - 47.8 J/mm3in vivo, translating to laser ablation efficiency of 0.023 - 0.500 mm3/J and 0.021 - 0.370 mm3/J, respectively. Laser ablation speeds ranged from 0.3 - 8.5 mm3/s in vivo, translating to lasing time consumption of 0.12 - 3.33 s/mm3. Laser efficacy ranged from 4.35 - 51.7 mm3/min in vivo. There was high heterogeneity for the terminology used to describe laser performance for the same metrics. CONCLUSIONS: The range of laser performance metric values relating stone volume to energy or time is wide, with corresponding differing terminology. We propose a standardized terminology for future studies on laser lithotripsy, including laser ablation efficiency (mm3/J), laser ablation speed (mm3/s), and laser energy consumption (J/mm3). Laser efficacy (mm3/min) is proposed as a broader term that is based on the total operative time, encompassing the whole technique using the laser. PATIENT SUMMARY: We reviewed studies to identify the units and terms used for laser performance when treating urinary stones. The review revealed a wide range of differing units, outcomes, and terms. Therefore, we propose a standardized terminology for future studies on laser stone treatment.

11.
World J Urol ; 41(12): 3807-3815, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37924335

RESUMO

INTRODUCTION: Shared decision making (SDM) in surgical specialties was demonstrated to diminish decisional regret, decisional anxiety and decisional conflict. Urolithiasis guidelines do not explicit patient preference to choose treatment. The aim of this review article was to perform a systematic evaluation of published evidence regarding SDM in urinary stone treatment. METHODS: A systematic review in accordance PRISMA checklist was conducted using the MEDLINE (PubMed) database. Inclusion criteria were studies that evaluated stone treatment preferences. Reviews, editorials, case reports and video abstracts were excluded. ROBUST checklist was used to assess quality of the studies. RESULTS: 188 articles were obtained. After applying the predefined selection criteria, seven articles were included for final analysis. Six out of seven studies were questionnaires that propose clinical scenarios and treatment alternatives. The last study was a patient preference trial. A general trend among included studies showed a patient preference towards the least invasive option (SWL over URS). The main reasons to choose one treatment over the other were stone-free rates, risk of complications and invasiveness. DISCUSSION: This review provides an overview of the patients' preferences towards stone treatment in small- and medium-sized stones. There was a clear preference towards the least invasive management strategy. The main reason was less invasiveness. This is opposed to the global trends of performing more ureteroscopies and less SWL. Physicians played a pivotal role in counselling patients. SDM should be encouraged and improved. The main limitation of this study is the characteristics of the included studies.


Assuntos
Litotripsia , Cálculos Urinários , Urolitíase , Humanos , Preferência do Paciente , Urolitíase/terapia , Cálculos Urinários/terapia , Ureteroscopia
13.
BJUI Compass ; 4(6): 613-621, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37818020

RESUMO

Introduction: Single use ureteroscopes are a technological innovation that have become available in the past decade and gained increased popularity. To this end, there are now an increasing number of both benchside and clinical studies reporting outcomes associated with their use. Our aim was to deliver a narrative review in order to provide an overview of this new technology. Methods: A narrative review was performed to gain overview of the history of the technology's development, equipment specifications and to highlight potential advantages and disadvantages. Results: Findings from preclinical studies highlight potenial advantages in terms of the design of single use ureteroscopes such as the lower weight and more recent modifications such as pressure control. However, concerns regarding plastic waste and environmental impact still remain unanswered. Clinical studies reveal them to have a non inferior status for outcomes such as stone free rate. However, the volume of evidence, especially in terms of randomised trials remains limited. From a cost perspective, study conclusions are still conflicting and centres are recommended to perform their own micro cost analyses. Conclusions: Most clinical outcomes for single use ureteroscopes currently match those achieved by reusable ureteroscopes but the data pool is still limited. Areas of continued debate include their environmental impact and cost efficiency.

14.
World J Urol ; 41(12): 3723-3730, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37831156

RESUMO

BACKGROUND: The novel pulsed thulium:yttrium-aluminum-garnet (p-Tm:YAG) laser was recently introduced. Current studies present promising p-Tm:YAG ablation efficiency, although all are based on non-human stone models or with unknown stone composition. The present study aimed to evaluate p-Tm:YAG ablation efficiency for stone dust from human urinary stones of known compositions. METHODS: Calcium oxalate monohydrate (COM) and uric acid (UA) stones were subjected to lithotripsy in vitro using a p-Tm:YAG laser generator (Thulio®, Dornier MedTech GmbH, Germany). 200 J was applied at 0.1 J × 100 Hz, 0.4 J × 25 Hz or 2.0 J × 5 Hz (average 10W). Ablated stone dust mass was calculated from weight difference between pre-lithotripsy stone and post-lithotripsy fragments > 250 µm. Estimated ablated volume was calculated using prior known stone densities (COM: 2.04 mg/mm3, UA: 1.55 mg/mm3). RESULTS: Mean ablation mass efficiency was 0.04, 0.06, 0.07 mg/J (COM) and 0.04, 0.05, 0.06 mg/J (UA) for each laser setting, respectively. This translated to 0.021, 0.029, 0.034 mm3/J (COM) and 0.026, 0.030, 0.039 mm3/J (UA). Mean energy consumption was 26, 18, 17 J/mg (COM) and 32, 23, 17 J/mg (UA). This translated to 53, 37, 34 J/mm3 (COM) and 50, 36, 26 J/mm3 (UA). There were no statistically significant differences for laser settings or stone types (all p > 0.05). CONCLUSION: To our knowledge, this is the first study showing ablation efficiency of the p-Tm:YAG laser for stone dust from human urinary stones of known compositions. The p-Tm:YAG seems to ablate COM and UA equally well, with no statistically significant differences between differing laser settings.


Assuntos
Lasers de Estado Sólido , Litotripsia a Laser , Litotripsia , Nefrolitíase , Cálculos Urinários , Humanos , Lasers de Estado Sólido/uso terapêutico , Túlio , Litotripsia a Laser/métodos , Cálculos Urinários/terapia , Oxalato de Cálcio , Hólmio
15.
Int. braz. j. urol ; 49(5): 646-647, Sep.-Oct. 2023.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1506415

RESUMO

ABSTRACT Introduction: The management of urolithiasis ectopic pelvic kidneys (EPK) can be challenging because of the aberrant anatomy (1-4). We demonstrate the step-by-step technique of the laparoscopic approach for treating urolithiasis in EPK. Patients and methods: Three men with EPK (2 left, 1 right) underwent laparoscopic pyelolithotomy through a transperitoneal approach. After establishing the pneumoperitoneum, the parietal peritoneum was opened at the parietal colic sulcus and the bowel displaced medially. The kidney was identified in the retroperitoneum and the renal pelvis exposed after removal of the perirenal adipose tissue. The renal pelvis was opened, and the stones were identified and retrieved with forceps in 2 cases and with a flexible nephroscope in 1 case. The renal pelvis was closed with a 3/0 running barbed suture. A DJ stent was placed in all patients. Results: For the first time, a laparoscopic technique for treating stones in the ectopic kidney is demonstrated in detail. Mean patient age was 52.6 years (44-58). The mean stone size was 22.3 mm (20-24 mm). Stones were in the renal pelvis in 2 cases and in the inferior calyx in 1 case. Mean operative time was 146 minutes (135-155 min). Mean estimated blood loss was 116 ml (60-140 ml). No complications were observed. The mean hospital stay was 3 days. The DJ stents were removed after 3 weeks. All patients were stone free at the postoperative CT scan with a mean follow-up of 3.3 months (1-6 months). Conclusions: Laparoscopic pyelolithotomy can be an effective and reproducible minimally invasive technique for treating urolithiasis in EPK.

16.
World J Urol ; 41(11): 3301-3308, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37682286

RESUMO

INTRODUCTION: Several preclinical studies about a novel pulsed-thulium:yttrium-aluminum-garnet (p-Tm:YAG) device have been published, demonstrating its possible clinical relevance. METHODS: We systematically reviewed the reality and expectations for this new p-Tm:YAG technology. A PubMed, Scopus and Embase search were performed. All relevant studies and data identified in the bibliographic search were selected, categorized, and summarized. RESULTS: Tm:YAG is a solid state diode-pumped laser that emits at a wavelength of 2013 nm, in the infrared spectrum. Despite being close to the Ho:YAG emission wavelength (2120 nm), Tm:YAG is much closer to the water absorption peak and has higher absorption coefficient in liquid water. At present, there very few evaluations of the commercially available p-Tm:YAG devices. There is a lack of information on how the technical aspects, functionality and pulse mechanism can be maximized for clinical utility. Available preclinical studies suggest that p-Tm:YAG laser may potentially increase the ablated stone weight as compared to Ho:YAG under specific condition and similar laser parameters, showing lower retropulsion as well. Regarding laser safety, a preclinical study observed similar absolute temperature and cumulative equivalent minutes at 43° C as compared to Ho:YAG. Finally, laser-associated soft-tissue damage was assessed at histological level, showing similar extent of alterations due to coagulation and necrosis when compared with the other clinically relevant lasers. CONCLUSIONS: The p-Tm:YAG appears to be a potential alternative to the Ho:YAG and TFL according to these preliminary laboratory data. Due to its novelty, further studies are needed to broaden our understanding of its functioning and clinical applicability.


Assuntos
Lasers de Estado Sólido , Litotripsia a Laser , Humanos , Lasers de Estado Sólido/uso terapêutico , Túlio , Temperatura , Água , Hólmio
17.
J Clin Med ; 12(17)2023 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-37685776

RESUMO

Flexible ureteroscopy (fURS) with laser lithotripsy is currently the gold standard surgical treatment for ureteral and kidney stones with a maximum diameter of 2 cm [...].

19.
World J Urol ; 41(10): 2823-2831, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37587366

RESUMO

PURPOSE: To evaluate whether stone dust can be obtained from all prevailing stone composition types using the novel pulsed thulium:YAG (p-Tm:YAG), including analysis of stone particle size after lithotripsy. METHODS: Human urinary stones of 7 different compositions were subjected to in vitro lithotripsy using a p-Tm:YAG laser with 270 µm silica core fibers (Thulio®, Dornier MedTech GmbH®, Wessling, Germany). A cumulative energy of 1000 J was applied to each stone using one of three laser settings: 0.1 J × 100 Hz, 0.4 J × 25 Hz and 2.0 J × 5 Hz (average power 10 W). After lithotripsy, larger remnant fragments were separated from stone dust using a previously described method depending on the floating ability of dust particles. Fragments and dust samples were then passed through laboratory sieves to evaluate stone particle count according to a semiquantitative analysis relying on a previous definition of stone dust (i.e., stone particles ≤ 250 µm). RESULTS: The p-Tm:YAG laser was able to produce stone dust from lithotripsy up to measured smallest mesh size of 63 µm in all seven stone composition types. Notably, all dust samples from all seven stone types and with all three laser settings had high counts of particles in the size range agreeing with the definition stone dust, i.e., ≤ 250 µm. CONCLUSION: This is the first study in the literature proving the p-Tm:YAG laser capable of dusting all prevailing human urinary stone compositions, with production of dust particles ≤ 250 µm. These findings are pivotal for the broader future implementation of the p-Tm:YAG in clinical routine.


Assuntos
Lasers de Estado Sólido , Litotripsia a Laser , Cálculos Urinários , Humanos , Lasers de Estado Sólido/uso terapêutico , Túlio , Poeira , Litotripsia a Laser/métodos , Cálculos Urinários/terapia
20.
World J Urol ; 41(9): 2541-2547, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37528287

RESUMO

PURPOSE: Aim of this study was to evaluate the effect of intravenous Y27632 (a ROK inhibitor) on intra-ureteral pressures and on blood pressure in an in vivo rat model for unilateral partial ureteral obstruction (PUO). METHODS: 15 Male Sprague Dawley rats were used. Under isofluran anesthesia, saline was continuously infused via polyethylene (PE)-10 catheters inserted in the ureters beneath the kidney pelvis. Left psoas muscle was sutured around the distal left ureter to create a partial obstruction. Carotid artery and femoral vein were cannulated with PE catheters for registration of mean arterial blood pressure (MAP) and for administration of drugs. Left and right ureter pressures and MAP were simultaneously recorded. Y27632 (0.03 and 0.1 mg/kg each n = 6-7) was given intravenously. T-test was used for comparisons. RESULTS: Spontaneous peristaltic pressure waves were recorded at baseline for both ureters. After the obstruction, Y27632 reduced maximum pressure (MaxP) by 10.5 ± 1.9% (0.03 mg/kg; p = 0.004) and 29.1 ± 4.8% (0.1 mg/kg; p < 0.001), minimum pressure (MinP) by 5.2 ± 2.3% (0.03 mg/kg; p = 0.02) and 12.2 ± 3.4% (0.1 mg/kg; p = 0.009), the area under the curve (AUC) by 7.8 ± 2.4% (0.03 mg/kg; p = 0.008) and 16.5 ± 3.7% (0.1 mg/kg;p = 0.007), the waves amplitude by 23.4 ± 11.3% (0.03 mg/kg; p = 0.098) and 38.7 ± 7.5% (0.1 mg/kg; p < 0.001), with no effect on contraction frequency. During simultaneous recordings from the normal ureter at the investigated doses, Y27632 reduced MaxP, MinP, AUC and waves amplitude by 1-7%. The MAP was reduced by 12.5 ± 5.3% (0.03 mg/kg; p = 0.07) and 15.8 ± 1.8% (0.1 mg/kg; p < 0.001). CONCLUSIONS: Y27632 decreased intra-ureteral pressures of a partially obstructed ureter with limited effect on blood pressure in an animal model of unilateral PUO.


Assuntos
Ureter , Obstrução Ureteral , Ratos , Masculino , Animais , Obstrução Ureteral/complicações , Quinases Associadas a rho , Ratos Sprague-Dawley
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...